  1. Romex exposed under covered patio | Information by Electrical ...

    Nov 6, 2024 · I'm working on making corrections on a residential inspection report for the sale of a home, one of the repairs the home inspector noted was the exposed romex running under a …

  2. That old Romex question again. | Information by Electrical ...

    Mar 12, 2022 · Hello all. Got a question. I am wiring an office building for a family member's used car lot. The building was a two story split level residential home with a basement that is being …

  3. How many wire per hole through studs | Information by Electrical ...

    Jan 2, 2020 · I have been told my whole career that you can only run two romex through a hole in a stud. You are allowed to run as many wires as you want through a...

  4. Romex outdoor application | Information by Electrical …

    Jan 4, 2023 · Can indoor romex be used in an outdoor structure if the ceiling is enclosed. Everything else on the structure is open. it will basically be cedar covering the rafter bays.

  5. Installing romex in EMT conduit | Information by Electrical ...

    Sep 20, 2022 · I also recently passed romex through a double gang metallic box without breaking wires out of jacket, straight in left to exit rear. Code requires equipment to be bonded if likely to …

  6. Romex Connectors installed from the inside of the box

    Jul 23, 2007 · Does anyone know of a romex connector that can be installed from the inside of an EXISTING junction box. I can't access the outside of the box without opening up the drywall, …

  7. Romex | Information by Electrical Professionals for Electrical ...

    Sep 6, 2013 · In the code book it says that you can install Romex if permitted as a Type 3, 4 or 5 building, but if it is permitted as a type 1 building you can not install Romex. Although IF the …

  8. Garage romex protection | Information by Electrical Professionals …

    Mar 29, 2010 · Where in the code is it required, (or not) the need to protect NM cable run in a garage, horizontally through bored holes in stud runs that are exposed (not covered with …

  9. Romex wiring in garage | Information by Electrical Professionals for ...

    May 8, 2015 · I'm buying a house and there is romex wiring run through the garage. The installation was approved by the township in 1987 when it was installed. Current standards …

  10. Types of conductors inside Romex cable | Information by Electrical ...

    Jul 16, 2014 · Are the individual conductors inside a piece of 14/2 or 12/2 Romex cable THHN or THWN type? What about those inside of an 8-3 or 6-3 Romex?